STOCK PRESSURE RELIEF VALVE ISSUES

One of the most common failures on the 2.0T FSI engine is the factory pressure-relief valve. These valves are in place to recirculate crankcase gases into the intake manifold once they open. Although this works fine for a few thousand miles, they begin to leak over time and cause boost to go past the valve into the valve cover. This not only causes an oily mess in the engine bay from crankcase pressure, but a rough idle, fuel economy decline and boost loss. With boost pressure far below where it should be, it is common to notice significant power losses and poor drivability.

IE PCV SOLUTION PLATE

Using our kit, you are able to completely remove the pressure-relief valve and replace it with a billet aluminum plate. This allows the factory breather system to function properly, while eliminating the failure-prone relief valve. With the hose between the valve cover and intake manifold completely eliminated, the included boost cap is used to block off the hose connection on the end of the intake manifold. Our billet cap features a tapped hole that can be plugged or used to plumb a boost gauge, compared to competitor’s products that do not offer a provision for plumbing a boost gauge.

Features:

  • Save your engine from a faulty pressure relief valve
  • Direct replacement & quick installation
  • IE boost cap has optional outlet for boost gauge
  • Bright black anodized finish
  • In-house CNC machined aluminum